4808 Nevada Trail UNIT 1
Air Conditioner Is Not Cooling
Photos
Completed
Days open: 16
Warranty / owner-preferred contractor
Additional details
Resident said: Air conditioner is not cooling
Additional Details: Unit has been sprayed down for debris and dust, and the air filter is current and good.
Probable Diagnosis: AC is blowing cold air but Home is Too Hot
MAX™ Also Learned:
- Has central air conditioning
Troubleshooting Steps:
- Entire home too hot
- Tried but failed to set thermostat correctly
- Vents were already open and clear
Permission to Enter: Yes
Assignment
AC Guys Heating and Cooling
Scheduled: -
Unit Maintenance Profile
View full unit profile
BA unit id: 127
•
PM unit id: 889901
HVAC / Filters
Air filter size
20x25x1
Last filter delivery date
2025-10-15
Other Notes
Maintenance key
No
Unit notes
To access crawl space, need to go through the bedroom closet.
Completion
Completion date
05-Mar, 4:23 pm
Completion notes
we identified that the condenser wasn’t running because the disconnect had burned out. We replaced it to eliminate any fire hazard. Second, once the system ran, the clogged drain line caused the float switch to shut off the condenser. Third, the float switch got stuck open and wouldn’t close, so we replaced it. Fourth, we flushed out the drain line to keep it clear. Finally, we sealed the coil on both sides, since it had been open. After all that, the system is now working properly
Messages
Visible to managers, vendors, residents, and owners
Send a message
Choose recipients, then send.
Recipients
Contacts
Assignment
AC Guys Heating and Cooling
This updates our dispatch assignment (and can differ from Property Meld until scheduled).
Technician / Vendor Assigned
AC Guys Heating and Cooling
Scheduled: -
AI Coordinator Assistant Click to expand
Suggestion
—