1712 Fitzgerald Court UNIT 1
Busted Water Pipe Outside- Owner Approved
Photos
Completed
Days open: 22
Warranty / owner-preferred contractor
Additional details
Resident said: Busted water pipe outside
Additional Details: It is the main line to either the unit im in or next door leaking. The leak is located at tree in front yard.
Probable Diagnosis: Pipe Leaking Unknown Source
MAX™ Also Learned:
- Unsure when leak began
Troubleshooting Steps:
- Water actively/continuously leaking
- Resident contained leak
Permission to Enter: Yes
Entry Notes: Someone will be home. Pets will be put up.
Assignment
Jorge ortiz
Scheduled: 02/26/2026
Unit Maintenance Profile
View full unit profile
BA unit id: 44
•
PM unit id: 890047
Unit maintenance sections are not available.
Completion
Completion date
26-Feb, 2:00 pm
Completion notes
We removed a 2x2 section of dirt where leak was coming from. We uncovered where leak of the source was and discovered that the fitting had broken. We removed approximately about a foot and a half of polybutylene pipe and replaced with pex and a new fitting. We tested line for leaks at the repair and monitor the meter fir about 15 mins and did not see any signs of usage. We wrapped fitting with protective tape and then covered opening back up.